NEWS

Wuyi Shengbu Sports Fitness Co., Ltd

Address:No.38,Development Rd,Wuyi 321200,Jinhua,Zhejiang,China.

Tel:0086-579-87680788

Foreign trade: 0086-0579-87615399

Fax:0086-579-87680789

Email:manager@shengbusport.com

Site:www.shengbusport.com

Company News
Home treadmill FAQs, and maintenance methods
Time:2016/2/27 Hits:10297

  (1) the treadmill automatically stops

  -Possible causes: 1, short circuit 2, internal line of 3, driver Board problem.

  -FIX: 1, please carefully check the line problems; 2, check the line; 3, the replacement driver Board.

  (2) electric treadmill can't accelerate

  -Possible causes: 1, instrument panel damage; 2, sensor break; 3, driver Board is bad.

  -FIX: 1, replacing the instrument panel; 2, replace sensors 3, the replacement driver Board.

  (3) the slip phenomenon in a treadmill running belt

  -Possible causes: 1, run through Bernard Husson; 2, ditch the treadmill belt too loose.

  -FIX: 1 balance, adjust the rear of the treadmill belt bolt (clockwise to the reasonable so far); 2, adjust the motor's position.

  (4) exercise any unusual noise

  -Possible causes: 1, due to the cover and the space between the running belt is toosmall, causing friction between cover and run with 2, possibly due to running in thecampaign between the running Board and involved foreign body; 3, run with too serious, and running boards on both sides of the conflict; 4: motor noise

  -FIX: correction or replacement 1, will cover; 2, removal of foreign body; 3, adjust the running balance; 4, replace motor.

  (5) why the treadmill does not start?

  -Possible causes: 1 the power is disconnected, 2, fuse 3, electric running machine switch broken; 4, other reasons, please contact our professionals.

  Solution: 1 check that the power supply; 2, replace fuse 3, replace the power switch.

  (6) the treadmill running belt the phenomenon of partial

  -Possible causes: 1 the imbalance between the front and rear axles, treadmill; 2, due to movements in the run position not very standard, both left and right feet is not,leading to partial.

  -FIX: adjust the wheel balance.

  (7) the treadmill exercise program error-prone?

  -Possible causes: 1, due to the instrument's cable is not plugged in; 2, instrument circuit board broken; 3, other reasons.

  -Solution: 1 check the three-segment connector; 2, replace the electronic form.

  (8) electric running machine motor noise

  -Possible causes: 1, carbon brush wear; 2, while the motor is running friction to thenext object.

  -FIX: 1, check or replace the carbon brush 2, removal of foreign bodies.

  (9) power on turn the power switch on the power supply LEDs do not light up

  -Possible causes: 1-phase is not plugged in place; 2, switch loose internal wiring; 3,three phase plug damaged; 4, switch may be damaged;

  -Solution: 1, try more than once; 2, open the upper cover check for loose wiring; 3,replace three-phase plugs 4, replace switch.

  (10) electronic table does not display

  -Possible causes: 1, control line not connected; 2, drive transformer is bad on the Board; 3, fuse burned; 4, power transistor burned;

  -Solution: 1 check the wiring first; 2, the replacement driver Board; 3, the replacement driver Board; 4, replace the drive Panel.

  (11) buttons don't work

  -Possible causes: 1, key age; 2, press the circuit board loose;

  -FIX: 1, replace keys 2, locking button circuit board.

  (12) not displaying

  -Possible cause: poor contact 1, LCD tablets; 2, liquid crystal films with long aging;

  -FIX: 1 locking circuit board securing screws; 2, replace the electronic form.

  (13) the heart cannot be tested

  -Possible causes: ear clip 1, heart damage; 2, heart rate circuit board damage;

  -FIX: 1, replace ear clip heartbeat; heartbeat 2, replaced the circuit board.

  (14) the display flashes

  -Possible causes: 1 poor contact, control line; 2 from electrostatic interference;

  -FIX: 1, connect the control cable 2, grounding wire is not connected.

  (15) the bursting phenomenon

  -Possible causes: 1, load too large; 2, runs too much friction between the belt and the running Board; 3, drive components on the plate is damaged; 4, a computer program error;

  -Solution: 1 reduce the load, replace the drive Panel; 2, add running boards maintenance oil, replace the drive Panel; 3, the replacement driver Board; 4, replace the electronic form.

  (16) the load stop

  -Possible causes: 1, drive torque didn't adjust well; 2, running with relatively loose;3, ribbed belts too loose; 4, running friction between the belt and the running Boardis too large;

  -Solution: 1 turn clockwise 1~2; 2, re-adjust walking belt; 3, re-adjusting ribbed belts; 4, add running boards maintenance oil.

  (17) the noise

  -Possible causes: 1, bearing damage caused the clicking sound of the drum 2, treadmill belt grinding noise, 3, the motor of fan Ye Sheng;

  -FIX: 1, replace drum; 2, clean run; 3, replace motor.

  (18) failed to start

  -May reasons: 1, and power switch not open; 2, and power not power; 3, and security switch didn't put good; 4, and control line damaged or didn't received bit; 5, and apart Shang shield, the even wiring has pine off; 6, and drive Board Shang of insurance tube destroyed; 7, and drive Board Shang of power tube burned; 8, and drive Board Shang of transformer damaged; 9, and motor burned;

  -FIX: 1, open the switch 2, call start; 3, put the safety switch 4, connect each connector that is on the line of control; 5, connect the internal connecting lines; 6, the replacement driver Board; 7, the replacement driver Board; 8, replace the drive Panel;9, motor was replaced before getting on the driver Board.

  (19) do not ascend

  -Possible causes: 1, press the connection cord is not connected; 2, ascending motorcontrol line not connected; 3, ascending motor connection cable is not loose; 4, drive control system for plate damage; 5, ascending motor damage;

  -FIX: after 1, check the connected; 2, checking connected; 3, checking connected;4, replacement drive Board; 5, replace the Ascension motor.

  (20) over time, the speed will stop automatically

  -Possible causes: 1, check that the safety switch is open, not in electronic form; 2, regular running boards you want to add oil 3, check whether the connected cable connection is bad

  -FIX: 1 put the safety switch, and then try; 2, adding treadmill oil 3, replace the wire.

  (21) while running feels not smooth

  -Possible causes: 1 check if the walking belt is too loose; 2, check the tank strap tooloose;

  -FIX: 1, adjusted according to manual instructions; 2, adjust the speed to a minimum, with foot steps running observed multi-grooved belt tension, adjustable front rollers, 3 Add a lubricating oil running boards, running boards.

  (22) after a period of use, feel vibrations more and more

  -Possible causes: 1, check the tank belt grooves 2, check whether the vibration generated by the motor; 3, check the front and rear drum wheel rotation is not normal;

  -FIX: 1, GOU chip removal clean; 2, need replacing; 3, replace drum.

  (23) after a period of use, there are different

  -Possible causes: 1, check the front and rear wheels Palin is damaged; 2, check themotor for carbon brush wear no uniform; 3, check the cover retaining screw is loose; 4, pulley speed of touch sensors 5, running inner run into foreign body;

  -FIX: 1, replace drum; 2, replacing carbon brushes 3, tighten the fixing screws 4, adjust the speed sensor to the appropriate location, 5, removal of foreign body.

  (24) after 5-10 seconds after starting, the meter E-1

  -Possible causes: 1, check the speed sensor wire connector is bad or loose; 2, sensor distance too far to the front wheel magnet, not sensing; 3, none of the above, you will need to replace the control panel or electronic form;

  -FIX: 1, speed sensor lock, and if the connection is bad, replace speed sensors 2, normal 2~3 mm; 3, SPEED-VR on the adjustment drive plate clockwise, repeat starting to adjust to the appropriate location.

  (25) the spreadsheet window shows lack of painting

  -Possible causes: 1, open the spreadsheet, check whether the PC Board retention screw lock;

  -FIX: 1, place the screw lock; 2, replace the electronic form.

  (26) the odor or smoke

  -Possible causes: 1, open the cover, check whether the connector short; 2, test themotor and load, then, whether the current exceeds the rated value;

  -FIX: 1, replace wiring; 2, if the motor current exceeds the rated value replaced 3,needs running boards add lubricating oil running Board on a regular basis (at leastmonthly), home once every seven days.

  (27) the electronic keys no action

  -Possible causes: 1, check that the safety switch is open, not in an electronic form,2, the connection cable is not properly;

  -FIX: 1, press the safety switch under 2, the line connected; 3, replace the electronic form.

  (28) the structure of leakage

  -Possible causes: 1, check the wiring and connection cable are broken skin, framework and short circuit 2, leakage control panel; 3, motor leakage;

  -FIX: 1, replace the wiring, 2, replace the control panel; 3, replace motor.

  (29) holding a heart rate value is too high or not responsive

  -Possible causes: 1, detect the Palm is not available when shaking or holding too tightly; 2, detected value exceeds 200, you need to test whether wires short-circuiting;3, check the sensor cable is dropped or bruised, and short-circuit the framework;

  -FIX: short circuit wires 2 1, replace, replacement of induction line 3, replace the control panel.

  (30) cannot speed up or slow down

  -Possible causes: 1, check whether the connected cable connector has bad contact;2, check whether the electronic meter button cable has broken \ broken \ off; 3, electronic form bad; 4, bad motor control board;

  -FIX: 1, replace wiring; 2, replace the electronic table 3, replace the control panel.

  (31) the electronic key failure

  -Possible causes: 1, check whether the electronic meter button cable has broken \ broken \ off or press the electronic floor has not been locked;

  -FIX: 1, open the spreadsheet, press circuit board retention screw lock; 2, replace the electronic form.

Tel:0086-579-87680788 Fax:0086-579-87680789 E-mail:manager@shengbusport.com
Http:www.shengbusport.com
ADD:No.38,Development Rd,Wuyi,Zhejiang,China

 Copyright © 2016 Wuyi Shengbu  Sports Fitness Co., Ltd.  All rights reserved.  Manage Sitemap Support: it579.net